认 证:工商信息已核实
访问量:120922
美国Teledyne 6400TSG紫外荧光分析仪 MODEL 6400TSG和MODEL 6400TSL分析仪基于紫外荧光分析原理,能对多种气体、液体物质中的总硫进行精确分析,测量精度高,操作简单。广泛应用于各种总硫分析。采用微处理技术,两个可设定量程,自动标定,自动量程切换。正压吹扫机柜形式,可适应多种危险区域的分析要求。
美国Teledyne 6400TSG紫外荧光分析仪
MODEL 6400TSG和MODEL 6400TSL分析仪基于紫外荧光分析原理,能对多种气体、液体物质中的总硫进行精确分析,测量精度高,操作简单。广泛应用于各种总硫分析。采用微处理技术,两个可设定量程,自动标定,自动量程切换。正压吹扫机柜形式,可适应多种危险区域的分析要求。
主要技术参数:
典型量程:
操作温度: 0-50°C
安装形式:独立柜体
危险区域:Class I Div 1 / Zone 1 ,Div 2 / Zone 2;
典型应用:
—甲烷变换过程总硫在线分析
—天然气中H2S、总硫在线分析
—食品级气体总硫在线分析
—燃油总硫在线分析
—各种气体、液体总硫在线分析
Model 6400-TSG Total Sulfur in Fuel Gas Analyzer
Using UV-Fluorescence detection technology
Model 6400-TSG Total Sulfur Analyzer
Download the brochure
Applications
Refinery flare monitoring - 40 CFR 60 Subpart Ja installations
Hydrogen plant steam methane reformer (SMR) for catalyst protection
LNG monitoring of sulfur impurities
Refinery feed gas to hydrogen plant
This Model 6400-TSG system uses UV-Fluorescence detection technology to analyze total sulfur concentration in gas samples. It consists of a Model 6400E UV Fluorescence Sulfur Dioxide Analyzer, a Flame Combustion Converter Module (FCCM), and associated sample handling required per application. The system is housed in a freestanding NEMA-4 or NEMA-4X rated enclosure with approved purge, making it suitable for operation in Class I Div 1 (Zone 1) or Class I Div 2 (Zone 2) environments.
Advantages
Trace and percent analysis ranges available
Continuous analysis - fast response time and no switching valves
Non-consumable sensing technology
High-temperature flame combustion converter module ensures complete sulfur conversion
Minimal preventative maintenance for less down-time
No pure oxygen required as a utility gas
Single and multiple sequenced stream configurations available
Speciating configurations available using integral chromatography
Class I Div 1 (Zone 1) and Class I Div 2 (Zone 2) configurations available
Theory of Operation
The undesirable sulfur compounds present (i.e. H2S, DMS, COS, CH3SH, CS2, etc) are converted into sulfur dioxide (SO2) under precisely controlled temperature and flow conditions.
SO2 + hv1 -> SO2*-> SO2 + hv2
When SO2 is exposed to UV light energy, hv1, it creates an "excited" form of sulfur dioxide, SO2*. A molecule in a high, vibrational level of the excited state, SO2*, will quickly fall to its lowest vibrational level by losing energy to other molecules through collision. Fluorescence occurs when the molecule returns to its electronic ground state. The intensity of the emitted light, hv2, is directly proportional to the total sulfur content found in the sample.
The converted sample gas is dried, then fed to the Model 6400E UV Fluorescence Analyzer where the SO2 Analysis takes place and is conveniently displayed as Total Sulfur.
Teledyne气体分析仪
美国Teledyne 6700 TOC分析仪 6700
美国Teledyne 6700 TOC分析仪 6700
美国Teledyne 6400TSG紫外荧光分析仪 6400TSG
美国Teledyne 6400TSG紫外荧光分析仪 6400TSG
美国Teledyne 6650水中油分析仪 6650
美国Teledyne 6650水中油分析仪 6650
美国Teledyne 6200T紫外分析仪 6200T
美国Teledyne 6200T紫外分析仪 6200T
美国Teledyne 6000紫外分析仪 6000
美国Teledyne 6000紫外分析仪 6000
美国teledyne 5020防爆近红外分析仪 5020
美国teledyne 5020防爆近红外分析仪 5020
美国Teledyne 5000近红外分析仪 5000
美国Teledyne 5000近红外分析仪 5000
美国teledyne 4060总苯分析仪 4060
美国teledyne 4060总苯分析仪 4060
美国Teledyne 4040非甲烷总碳氢分析仪 4040
美国Teledyne 4040非甲烷总碳氢分析仪 4040
美国Teledyne 4030高温型总碳氢分析仪 4030
美国Teledyne 4030高温型总碳氢分析仪 4030
美国Teledyne 2010A热导气体分析仪价格 2010A
美国Teledyne 2010A热导气体分析仪价格 2010A
美国Teledyne AN300便携式氮分析仪 AN300
美国Teledyne AN300便携式氮分析仪 AN300
美国Teledyne 2020热导分析仪 2020
美国Teledyne 2020热导分析仪 2020
美国Teledyne 4020总碳烃分析仪 4020
美国Teledyne 4020总碳烃分析仪 4020
美国Teledyne热导分析仪2000A 2000A
美国Teledyne热导分析仪
- 推荐产品
- 供应产品
- 产品分类
- 德国retsch拍击式筛分仪AS 200 tap
- Torch总有机碳分析仪
- 德国retsch分析筛
- 德国retsch Sieve Shaker AS 450 basic
- 德国retsch AS 200
- 德国retsch分样仪PT 100
- 德国retsch超声波清洗仪UR
- 德国retschTester AT 100 XL
- 德国retsch筛分仪AS 300 control
- 德国retsch筛分仪AS 200 basic
- 絮凝器
- 德国retsch进样仪DR 100
- 耶拿contrAA®300火焰原子吸收光谱仪
- 德国retsch筛分仪AS 200 digit cA
- 德国retsch筛分仪AS 200 control
- 德国retsch Sieve Shaker AS 450 control